4SRB Engines: Existing, New, & Reconstructed Units Site-Rated>500 HP at HAP major-source facilities
Required Performance
76% reduction of formaldehyde or 350 ppbvd at 15% O2 – Note: Any technology can be used to meet the standards – Performance tests must be conducted at 100% load ± 10%.
Testing
Initial performance test required – ASTM or formaldehyde test methods (FTIR orAcetylacetone only – no CARB 430 or EPA SW-846 Method 0011).
Semi-annual performance tests for formaldehyde – going to annual testing after two tests demonstrating compliance.
Monitor
If NSCR catalyst is used, continuous monitoring for catalyst inlet temperature (750-1250 °F min/max), with 4-hour rolling average. Pressure drop to be measured monthly and maintained within ±2” WC of the pressure drop measured during the initial performance test.
If other technology used, petition EPA Administrator for approval of parameters/no-parameters.
4SLB Engines: New, & Reconstructed Units Site-Rated>500 HP at HAP major-source facilities
Required Performance
93% reduction of CO or 14 ppmvd formaldehyde at 15% O2 – Note that any technology can be used to comply with either of the limits – also note that performance test to demonstrate compliance is only at 100% load ±10%.
Testing
Initial performance test required – using CO portable method from ASTM or formaldehyde test methods (FTIR or Acetylacetone only – no CARB 430 or EPA SW-846 Method 0011)
Semi-annual performance tests for CO or formaldehyde – going to annual testing after two tests demonstrating compliance. Also option to use CO CEMS.
Monitor
If oxidation catalyst is used, continuous monitoring for catalyst inlet temperature (450-1350 °F min/max), with 4-hour rolling average. Pressure-drop to be measured monthly and maintained within ±2” WC of the pressure drop measured during the initial pressure test.
If other technology is used, petition EPA Administrator for approval of parameters/no-parameters.
2SLB Engines: New & Reconstructed Units Site-Rated>500 HP at HAP major-source facilities
Required Performance
58% reduction of CO or 12 ppmvd formaldehyde at 15% O2 – Note that any technology can be used to comply with either of the limits – also note that performance test to demonstrate compliance is only at 100% load ±10%.
Testing
Initial performance test required – using CO portable method from ASTM or formaldehyde test methods (FTIR or Acetylacetone only – no CARB 430 or EPA SW-846 Method 0011)
Semi-annual performance tests for CO or formaldehyde – going to annual testing after two tests demonstrating compliance. Also option to use CO CEMS
Monitor
If oxidation catalyst is used, continuous monitoring for catalyst inlet temperature (450-1350 °F min/max), with 4-hour rolling average. Pressure-drop to be measured monthly and maintained within ±2” WC of the pressure drop measured during the initial pressure test.
Definitions
HAP major-source = 10 TPY of any single HAP or 25 TPY any combination of HAPs.
HAP – Typically acetaldehyde, benzene, formaldehyde, and toluene.